[ Polski ][ Deutsch ]Two- and Three-Dimensional heat flow Patterns

The method of analysis most commonly practiced today when evaluating the thermal performance of building spaces, components, and assemblies is based on a simple, one-dimensional, constant flow model of heat conduction (i.e. the assumption of parallel heat flow for the calculation of U-values and areas). Such an assumption often leads not only to multidimensional thermal heat bridge analysis with AnThermdisappointing results in the thermal quality of realized construction projects, but also to costly consequences due to

  • unforeseeably high energy consumption for heating,
    as well as
  • damage caused by surface and core condensation and moisture.

These potentially negative consequences of over-simplification, inherent to the assumption of one-dimensionality, are becoming increasingly critical in today's trend towards highly insulated building structures. If the effects of thermal bridges are neglected, drastic errors in estimating heating requirements are bound to result, particularly when assessing energy efficient buildings.

Multi-dimensional (i.e. two- and three-dimensional) evaluations of thermally critical regions within a building assembly, especially those with heat bridges, during early design phases can provide valuable preliminary information to support the decision-making process, thus leading to considerably more reliable design results.

Surface moisture due to condensation (typically occurring in such regions as floor-wall connections, window installations, etc.) as well as mould growth in humid environments can also be effectively prevented by means of multi-dimensional evaluation during planning and detail design.
 

Interested? Contact us for more information.

Or try and evaluate the demonstrational version just now!

Home
Wärmebrücken berechnen (AnTherm)
Psi-Wert Rechner
U-Wert Rechner
Luft-Hohlraum Rechner
Grenzfeuchte (Kondensfeuchte) Rechner
METEONORM - Klimadatenbank und Wettergenerator
Thermal Bridges Calculation (AnTherm)
Psi-Value Calculator
U-Value Calculator
Air Cavity Calculator
Condensing Humidity (dew point) Calculator
METEONORM - Climate- and Weather Generator
Mostki cieplne (AnTherm)
METEONORM - generator Klimatu i Pogody
CE Gefährdungsanalyse MaschCE
CE Hazard Analysis MaschCE
CE Analiza zagrozen MaschCE
SolRad3 Sonnenstrahlung
GEBA Gebäudesimulation
Bücher Bauphysik

AnTherm
Thermal Bridges
Features & Attributes
+ New Version +
Instrumentation
European Standards
Conformance
Vapor Diffusion
Example results
+ Capability Variants +
Super-Refinement

Demo & Downloads
Visualization
3D Navigation
System Requirements
# Help & Tutorials #
Product life cycle
Training & Seminars
Diploma & Projects
>>> News <<<
>>> Ordering <<<
>>> Prices <<<

 

Visit AnTherm Blog ...
Visit AnTherm Gallery ...
Visit AnTherm Videos ...
Search & Find ...
Sitemap
 

Copyright © Kornicki Dienstleistungen in EDV & IT