Probe Points / Extreme (min/max) Locations window
The window Probe Points is used to input any number of arbitrary points for which the Probe Points report shall be generated (second part of Results report). The list of probe points can be extended from the Result 3D window (Probe) also (by "Collect point"). The Min/Max tab of the window lists interesting locations with extreme values (e.g. points lowest and highest temperatures at surfaces of all spaces and within the interior of all power sources) thus providing the ability to select them for further evaluation. This read only listing is automatically provided and updated as soon as any boundary conditions have been applied to the solution.
The input is confirmed by pressing the button Apply. The second part of Results report will show evaluation of temperatures for all points (x, y, z coordinates) entered in this window. If some point does not belong to the interior of the construction no temperature values will be shown in the corresponding line of the report. Probe points entered are saved to the project file. Remark: Similar evaluation of one probe point is available within graphical results of the application. Remark: The active tab will be saved upon the window is closed together with the application settings (LastSelectedProbePointsFormTabPageName) and restored when this window is opened again. Remark: While "Collect Point" (e.g. out of "Results 3D window") is requested the window will switch to the "User" tab where the new probe point will be appended.
|
|